Do you have a very difficult underground tank
application that includes a high water table, extreme depths or traffic
loads? Get on board patented Tanksmart™ technology.
Onsite goes beyond tanks. We now stock a
wide range of Polylok onsite accessories, including lids, risers, field
accessories, effluent filters and more. Additonally, we are pleased to supply
the Alberta onsite market ARC chambers by Hancor.
Onsite Wastewater Treatment Systems are the future of the
onsite industry, and Bionest is at the leading
edge. Clean water systems for households and
developments are available now.
Are you ready for 2010 when all fuel slip tanks must
be Transport Canada certified? Get on board now with an Enviroslip
premium dual wall fuel slip tank. Click here to find out why this will save you
money in the long run.
Monitor water levels in septic tanks, holding tanks, pump chambers, cisterns, sumps, floor drains or truck tanks.

The indoor alarm will warm of a threatening level condition.
Green - power on, monitoring
Red flashing and audio - alarm condition
Yellow - probe or wireless communication error
Audio chirp - low batteries in outdoor unit
Audio can be silenced with the mute button. Audio will resent when the alarm condition is corrected.
High or low level function is selected during initial installation. HIGH LEVEL alarm condition occurs when the liquid level rises around the probe. An example is a septic tank. LOW LEVEL alarm condition occurs when the liquid falls below the probe. An example is a water cistern.
The wireless version (110) has a range of 70m (300 ft). 4 AA batteries are good for 3 years under normal working conditions.

• Indoor digital display of water depth
• Digital RF sensor with +- 3/8" resolution throughout span
• Configurable HIGH and LOW alarm points
• Audible alarm auto reset
• Self diagnostic functions
• Outdoor junction box
• Standard sensor length 1.5m (5feet)
Monitor the water level in pump chambers, cisterns, holding tanks, sumps or truck tanks. The indoor digital display indicates the depth of water in feet or meters or percent.
HIGH and LOW level alarm points are programmed using the display. An audible alarm with auto reset can be used to warn of an alarm condition.
The sensor rests, vertically, on the bottom of the tank and is tethered at the top. The sensor cable is terminated to customer supplied cable in the weatherproof junction box. Customer supplied cable terminates at the plug on the indoor display.
On the Model 200C four relay outputs can be configured to operate pumps, remote alarms, security systems or other control applications.
• Power supply 120VAC, 60 Hz, UL listed and CSA
• Indoor display - 4 digit LED, programmable HIGH
• Sensor - Sealed 1 1/2" PVC pipe, 3m (9') SJOOW
• Custom sensor lengths, 0.9m (3 feet) to 4.8m (16 feet)
• Analog output 1-5 VDC, digital output RS232 (200C only)
• Custom control or data logging applications (200C only)